CLINICAL EVENTS CALENDAR
Non-Accredited Education

CLINICAL EXPERIENCE WITH A NEW HYBRID CORONARY WIRE
On Demand Web ArchiveNon-Accredited
Target Audience: Physicians, nurses, and technologists.
This activity is supported by an educational grant from Terumo Medical Corporation.
The Use of the Aorto-Uni-Iliac Device in the Treatment of Abdominal Aortic Aneurysms
1Jeffrey H. Freihage, MD, 2Aravinda Nanjundappa, MD, RVT, 3Pranab Das, MD, 1Robert S. Dieter, MD, RVT
Author Affiliations:
From 1Loyola University, Maywood, Illinois, 2East Carolina University, Greenville, North Carolina, and 3Memphis Medical Center, Memphis, Tennessee.
Correspondence: Robert S. Dieter, MD, RVT, Assistant Professor of Medicine, Vascular and Endovascular Medicine, Interventional Cardiology, Loyola University, 2160 S. First Ave., Maywood, IL 60153.
E-mail: rdieter@lumc.edu.
Disclosure: The authors report no financial relationships or conflicts of interest regarding the content therein.
___________________________
Endovascular repair of abdominal aortic aneurysms (AAA) has become an accepted and often preferred method of therapy. However, the influence of endograft design (i.e., bifurcated versus aorto-uni-iliac [AUI]) on outcomes is unknown. In this issue of Vascular Disease Management, the authors of the article “Whether Bifurcated Endografts Perform Better Than AUI” attempt to give insight into the issue of graft design on long-term outcomes.1 In their study, they retrospectively compare the outcomes of patients in the Eurostar database and their own database who had received either the bifurcated design versus the AUI design.
In this nonrandomized retrospective review, the authors found that patients who received an AUI device were more likely to be older, have larger aneurysms, be unfit for open repair, and have occlusion of a common iliac artery. Despite the differences in patient demographics, both stent designs performed equally well in terms of graft-related complications: endoleak rate, graft migration, graft reintervention, aneurysm rupture, and pseudoaneurysm formation during short- and long-term follow up. Importantly, the authors discovered in both the Eurostar series and their own personal series that patients who underwent repair with an AUI device had a significantly higher mortality during long-term follow up, relative to those who underwent repair with the bifurcated design. Most importantly, the aneurysm related mortality after 7 years was similar between both stent design groups.
The retrospective review presented in this issue gives important data on the utility of the AUI device for the treatment of AAA. Importantly, the authors report that relative to those who receive a bifurcated stent design, the rate of graft-related complications is quite similar, despite insertion of the AUI device in an older patient population with more comorbidities and larger aneurysms.
Although, this study lends evidence to the utility of the AUI device for treatment of the AAA, caution must be exhibited in the interpretation of the data. Primarily, the retrospective nature of the trial raises concern for treatment bias. Although the AUI device is an important tool in the treatment of AAA, the applicability to all patients must be done with caution. The number of patients who received the AUI device (389) is a very small sample, relative to those who received the bifurcated stent design (5918). Only 6.2% of all patients analyzed in this review received the AUI design. This finding is important, as we do not know the long-term patency of a femoral artery to a femoral artery bypass graft. By placing the AUI stent, the blood supply to both limbs are at risk if the iliac portion of the device has a mechanical complication.
Finally, many of the patients who received the AUI design were patients who were not deemed surgical candidates due to their comorbidities. This same patient population was studied in EVAR II and found to have similar mortality with endovascular repair versus medical therapy. Thus, the increased all-cause mortality in the AUI group may be due to the increased comorbidities of the patient population. We, as an endovascular community, must continue to be critical of our selection criteria for AAA.
In conclusion, the article by Riambau and Hobo lends evidence that the AUI device is an important tool for the treatment of AAA, with a similar rate of graft-related complications as the bifurcated design.
1. Riambau V, Hobo R. Whether bifurcated endografts perform better than aorto-uni-iliac. Vascular Disease Management 2008;5:164–168.
- Login or register to post comments
- Email this page
|
Using Advanced Technology to |
|
Superior Mesenteric Artery Revascularization and |
Vascular Disease News Wire
- Thursday, December 11, 2008 - 16:23
- Monday, November 24, 2008 - 11:56
- Monday, October 6, 2008 - 10:02
Anytown, California
CME Showcase
"Diabetic Peripheral Neuropathy"
Upcoming Accredited Webcast Release Date: December 22, 2008 Expiration Date: December 22, 2009 This activity is supported by an educational grant from PamLabs. To register for this Webcast, visit www.naccme.com/program/n-558/ |
![]() LUMEN 2009 - THE SYMPOSIUM ON OPTIMAL TREATMENTS FOR ACUTE MI Live Symposium Date: February 26-28 Location: Loews Miami Beach Hotel Miami Beach, Florida 33139 Phone: (305) 604-1601 Toll Free: 1-877-563-9762 This activity is sponsored by the North American Center for Continuing Medical Education. |
![]() CARDIAC PET: Optimizing CAD Patient Management with Diagnostic Confidence A Complimentary CME Accredited Lunch Symposium Date: Friday, September 12, 2008 12:00 pm - 1:15 pm Location: Hynes Convention Center 900 Boylston Street, Room 304 Boston, MA 02115 This activity is supported by an educational grant from Bracco Diagnostics Inc. |